Wood and Coal Gasification Boilers

The boilers are constructed for burning wood and coal on the principle of generator gasifying with the use of a gas exhaust ventilator, which withdraws the combustion gases from the boiler.

The boiler body is produced as a weldment of 3-8 mm steel sheets. The boiler consists of two chambers, one placed upon the other. The upper chamber makes up the fuel container, and the lower one, combustion chamber and ash collector. Between the two chambers, a new, rotating, patent protected grate is placed. The grate ensures perfect combustion of coal, wood, or a combination thereof, as well as simple cleaning.

Advantages of Wood and Coal Gasification Boilers

  • Burning coal and wood separately, we recommend together
  • Revolving furnace grate - easy for ash removal
  • Fan controlled - pressure(S)
  • Simple handling and cleaning
  • Large fuel container
  • Revolving furnace grate - easy for ash removal
  • The boiler contains no tubing - simpler cleaning (Except C50S)
  • The secondary air is pre-heated to high temperatures
  • Small size and low weight
  • High quality
The exhaust fan when compared with a pressure fan exhausts combustion products and minimises smoke during stoking and boiler operation.
The settings of the grate segments is displayed on the picture, and the same for use of coal or wood.

The secondary air supply channel and the flat part of gasifying grate must always point downwards.

PATENTS PROTECTED!

Installation

ATMOS boilers must be connected via the LADDOMAT 21 or ESBE thermoregulation valve to achieve and keeping the minimum temperature of water returning to boiler at 65°C. The temperature of water exiting the boiler must be permanently kept between 80 - 90°C. The default configuration of all boilers includes a cooling circuit to prevent overheating. We recommend installing boilers with accumulation tanks.

Boiler regulation

Electrical - mechanical - Power is controlled with a safety valve operated with the draught regulator, FR 124 type, which automatically opens or closes the safety valve according to a set output temperature of water (80 - 90°C). When setting the power regulator, much attention should be paid because the regulator has another important function other than power regulation - it also secures the boiler against overheating. A controlling thermostat located on the boiler panel regulates the fan according to a set temperature (75 - 85°C). A temperature lower by 5°C should be set on the controlling thermostat rather than on the FR 124 draught regulator. Boiler use: C 18S, C 20S, C 30S, C 40S, C 50S.

Each boiler can be fitted with ATMOS ACD 01 equithermal controller. It takes a control of the heating system based on datas collected from external sensors and on time. It can control suction fan of the boiler as well.

diagram

1. Boiler drum 14. Fireproof and heat-resisting fitting - GS - rear face of round space
2. Filling door 15. Cleaning cover
3. Ash pan door 16. Furnace grate level
4. Ventilator - pressure (S) 17. Firing safety valve pull rod
5. Fireproof and heat-resisting fitting - rear block 18. Thermometer
6. Control panel 19. Furnace curtain - front
7. Safety thermostat 20. Switch
8. Regulating safety valve 22. Power regulator - Honeywell FR124
9. Grate bar 23. Fireproof and heat-resisting fitting - front block
10. Fireproof and heat-resisting fitting - round space L + P 24. Ventilator thermostat
11. Furnace grate tube 25. Door panel - Sibral
12. Fireproof and heat-resisting fitting - half-moon 26. Door insulating cord - cord 18x18
13. Firing safety valve 27. Waste gas thermostat
    28. Cooling loop to prevent overheating


A B C D E F G H CH I J
C 18S 1180 770 590 872 152 70 200 930 220 190 6/4"
C 20S 1420 770 590 1118 152 70 200 1165 220 190 6/4"
C 30S 1420 870 590 1118 152 70 200 1165 220 190 6/4"
C 40S 1420 970 590 1118 152 70 200 1165 220 190 2"
C 50S 1420 1120 590 1118 152 70 102 1177 220 220 2"

TECHNICAL DATA
BOILER TYPE Kombi
C 18S C 20S C 30S C 40S C 50S
Operating interval (kW) 14 - 20 17 - 25 22 - 32 28 - 40 35 - 48
Req. chimney Exhausted (Pa) 22 25 25 28 28
Boiler weight (kg) 225 298 336 376 415
Water volume (l) 45 64 64 77 95
Fuel container volume (dm3) 66 100 125 150 150
El. power consumption (W) 50 50 50 50 50
Operating voltage (V/Hz) 230/50
Required fuel Brown coal of walnut size with specific energy 17-20 MJ/kg
Dry wood with specific energy 15-18 MJ/kg, diameter 70-90 mm,
12 - 20% moisture level
Max. length of wood (mm) 330 330 430 530 530
Min. operating temperature of return water 65 °C
Efficiency within the power output interval 81 - 85% 81 - 84% 81 - 84% 86 - 87% 86 - 87%
Boiler class 3

 

Black coal boilers ATMOS AC25S

The boilers are constructed to burn NUT 1 black coal and wood. On a base of gasification process with a suction fan (S) to suck waste gasses into the chimney.

The boiler body is produced as a weldment of 3-8 mm steel sheets. The boiler consists of two chambers, one placed upon the other. The upper chamber makes up the fuel container, and the lower one, combustion chamber and ash collector. Between the two chambers, a new, rotating, patent protected grate is placed. The grate ensures perfect combustion of coal, wood, or a combination thereof, as well as simple cleaning. The primary and secondary air are pre-heated to a very high temperature for achieveing high efficiency and good quality burning.

The recommneded fuel is NUT 1 black coal. As domestic fuel, logs of wood (length 330mm), brown and black coal of a larger size (NUB), or brown-coal and wooden briquettes can be used.

Advantages of Black coal boilers ATMOS AC25S:

  • Burning coal and wood separately, we recommend together
  • Large fuel container
  • Simple handling and cleaning
  • Coolining loop protecting the boiler against overheating
  • Revolving furnace grate - easy for ash removal
  • The boiler contains no tubing - simple cleaning
  • The secondary air is pre-heated to high temperatures
  • Small size and low weight
  • Fan controlled - pressure(S)
  • Automatic switching off the boiler after burning down

Boiler Regulation

Electrical - mechanical - Power is controlled with a safety valve operated with the draught regulator, FR 124 type, which automatically opens or closes the safety valve according to a set output temperature of water (80 - 90°C). When setting the power regulator, much attention should be paid because the regulator has another important function other than power regulation - it also secures the boiler against overheating. A controlling thermostat located on the boiler panel regulates the fan according to a set temperature (80 - 85°C). A temperature lower by 5°C should be set on the controlling thermostat rather than on the FR 124 draught regulator. Boilers contain waste gas thermostat which serves to stop the suction fan when the boiler burns down. The boilers work for 70% without the fan on.

Each boiler can be fitted with ATMOS ACD 01 equithermal controller. It takes a control of the heating system based on datas collected from external sensors and on time. It can control suction fan of the boiler as well.

black coal diagram

Legend – AC25S

Dimensions AC25S
A 1180
B 770
C 590
D 872
E 152
F 65
G 200
H 933
CH 220
I 190
J 6/4"

 

TECHNICAL SPECIFICATIONS
ATMOS KOMBI TYPE
  AC25S
Energy output (black coal) kW 20-26
Energy output (wood) kW 15-20
Weight of boiler kg 235
Volume of water in boiler l 45
Dumping hopper capacity dm3 66
Electrical input W 50
Electric network V/Hz 230/50
Specified fuel Black coal - NUT 1, calorific value 18-28 MJ/kg
Domestic fuel Dry wood ø 50-120 mm, moisture 12-20%
Max. length of wood mm 330
Min. temperature of returned water °C 65
Efficiency % 84
Quality of combustion - CO mg/m3 <500
Boiler class - 3



Wir über uns
Import/Export
Leistungen
Products
- Boilers
  Wood pellet boilers
  Combined Wood, Pellets, Gas, LFO Boilers
  Wood gasification boilers
  Wood and coal gasification boilers
  Services
  Info
  Download brochures
  Download manual instructions
  Download certificates and test reports
  Nature Energy Pellets
- Stoves
Strich Navigation
- Storage tanks
Strich Navigation
- Solar products
Strich Navigation
- Pellet silos
Strich Navigation
- kitchen stoves
Stellenangebote